Electrical design and 33 kV connection approvals
Khabir holds Etihad Water & Electricity consultant licence No. 0403 at Category 1. In practice that means there is no upper limit on the connected load we are permitted to design and submit, and we are authorised for medium voltage distribution up to 33 kV. Most consultancies in the Northern Emirates are limited to a few hundred kilowatts, and a Category-1 licence is what allows a project to grow from a villa to a resort without changing engineer of record part way through.
We are an independent consultancy. We do not install cable, we do not supply switchgear, and we take no margin on equipment. The drawing we produce is the drawing the authority reviews, and the inspection report we write is written for the owner rather than for the contractor.
What the electrical scope covers
Connected load schedules and diversity
Every circuit is listed, grouped and diversified against the actual pattern of use rather than a blanket factor. An honest diversity calculation is often the difference between paying for a 630 kVA transformer and paying for a 1000 kVA one.
Single line diagrams (SLD)
The document the authority reads first. It shows the incoming supply, the metering arrangement, main and sub distribution, protection ratings and earthing, in the format Etihad Water & Electricity expects to receive.
Substation and transformer sizing
Transformer rating, cooling, location, clearances and civil requirements coordinated with the architect early enough that the substation room does not have to be redrawn later.
Cable sizing and voltage drop
Sized for current carrying capacity, short circuit withstand and voltage drop across the real route length, not the straight line distance on the plan.
Protection and discrimination
Breaker ratings and settings chosen so that a fault on a final circuit trips that circuit and nothing upstream of it.
Earthing and lightning protection
Earth electrode arrangement, equipotential bonding, and a lightning protection risk assessment where building height or exposure calls for one.
Generator and ATS schemes
Standby generator sizing, changeover arrangement, and the load segregation that decides what stays alive during an outage.
Small power, lighting and lux calculations
Lighting layouts backed by illuminance calculations, so each space is lit to the level its use actually requires.
How a connection approval actually runs
- Load assessment. We start from your architectural drawings and the intended use of each space, and build the connected load from first principles. If the load you have been quoted looks inflated, this is the stage where it gets corrected.
- Design and submission set. Load schedule, single line diagram, layout drawings and supporting calculations, assembled in the format Etihad Water & Electricity reviews.
- Authority review. We submit under our Category-1 licence and handle the queries directly. Comments come back to us, not to you.
- Approval and connection. Approved drawings, connection agreement, metering arrangement and energisation.
Standards we design to
- IEC 60364 low voltage electrical installations
- Etihad Water & Electricity regulations for electrical installations
- IEC 60909 short circuit current calculation
- IEC 62305 protection against lightning
- UAE Fire and Life Safety Code of Practice, for supplies to life safety systems
Where we do this work
Khabir is based in Ras Al Khaimah and delivers electromechanical engineering consultancy across the United Arab Emirates — Dubai, Ras Al Khaimah, Abu Dhabi, Sharjah, Ajman, Umm Al Quwain, Fujairah — including industrial parks and free zones such as RAKEZ, Al Hamra Free Zone, Dubai Maritime City, and JAFZA. Our Etihad Water & Electricity Category-1 consultant licence (No. 0403) provides unlimited kilowatt connected load approval across the Northern Emirates, while our Civil Defence, Etisalat, and MEP site supervision capabilities cover projects nationwide.
Common questions
What does Category-1 mean for my project?
A Category-1 consultant licence carries no upper limit on connected load and permits medium voltage design up to 33 kV. Lower categories are capped, which means a project above that cap has to change consultant part way through and re-submit. Khabir holds Category-1 licence No. 0403.
Can you increase the connected load on an existing building?
Yes. A load enhancement application needs a revised load schedule, an updated single line diagram, confirmation that the existing cable and switchgear can carry the new load, and a submission to Etihad Water & Electricity. We prepare all of it and submit under our licence.
Do you design the substation as well?
We size and specify the transformer, position the substation, define the clearances and civil requirements, and coordinate with the authority. The substation itself is then built by the contractor to that design.
How long does an electrical approval take?
The design set is usually ready within one to two weeks of receiving complete architectural drawings. Authority review time varies with the emirate and the size of the load, and we follow it up until the approval is issued.
Send us the drawings
Email or WhatsApp your architectural drawings or load requirements. We review them and come back with a clear scope, timeline and fee proposal within two working days.